BIS & IS Standards Compliant, QCO-Ready Testing Equipment, Pan-India Installation & Support

Polymer, Pipes & Fittings Testing Equipment

View all equipment

Comprehensive range of polymers, pipes and fittings testing machines designed and manufactured to meet all BIS standards with superior accuracy and reliability.

Our company manufactures testing machines catering to the full range of polymer, pipes & fittings categories aligned with mandatory Indian Standards (IS codes). Each machine is designed to meet the specific IS testing requirements, ensuring full compliance across these categories.

BIS standards and indicative tests for polymer pipes and fittings used in water supply, sewerage and plumbing.
ItemIS CodeKey Tests
UPVC Pipes (Water Supply)IS 4985 Dimensions, Hydrostatic (ambient/elevated, short/long-term), Opacity, Heat reversion, Resistance to external blows (TIR), VST, Density, Sulphated ash, Visual/marking.
SWR Pipes (PVC-U)IS 13592 Dimensions &, sockets, Impact (TIR), Heat reversion, VST, Watertightness of joints, Stress-relief, Tensile strength, Axial shrinkage (Type-B), Effect of sunlight, Effect on water, Resistance to sulphuric acid, Resistance to dichloromethane (DCM), Visual/marking.
PVC-U Sewerage/Drainage PipesIS 15328 Dimensions, Ring stiffness class, Impact, Heat reversion, VST, Joint water-tightness, Hydrostatic (where applicable), Visual/marking.
HDPE Pipes (Water Supply)IS 4984 Dimensions/SDR, Hydrostatic (20 °C &, elevated, short/long-term), Density, MFR, Carbon black content &, dispersion, OIT, ESCR, Tensile &, elongation at break, Butt-fusion tensile, Slow-crack growth (SCG), Overall migration (potable use), Visual/marking.
HDPE Sewerage Pipes (Non-pressure)IS 14333 Dimensions, Density, MFR, Carbon black content &, dispersion, OIT, Hydrostatic (acceptance/type), Elongation at break, Tensile (from pipe), Slow-crack growth (SCG), Reversion, Visual/marking.
Casing/Screen Pipes (PVC-U)IS 12818 Dimensions (OD/ID), slot width &, open area, Hydrostatic (internal), Collapse pressure (external), Tensile of threaded joints, Impact, Thread gauging, Visual/marking.
PPR Pipes (Hot &, Cold Water)IS 15801 Dimensions, Hydrostatic at multiple temperatures (20–95 °C, including long-term at 95 °C), Influence on water, Longitudinal reversion, Visual/marking.
CPVC Pipes (Hot &, Cold Water)IS 15778 Dimensions, Hydrostatic (20 °C/1 h, 95 °C/165 h &, 1000 h, 95 °C/8760 h for thermal stability), VST, Heat reversion, Opacity, Resistance to external blows (0 °C), Flattening, Tensile strength, Effect on water, Density, Visual/marking.
CPVC FittingsIS 17546 Sustained-pressure tests, Burst-pressure tests, Thermal cycling / leak-tightness (assemblies), Dimensions, Marking.
PVC-U Fittings (Water Supply)IS 7834 Dimensions, Hydrostatic / leak-tightness (where applicable), VST, Heat reversion, Visual/marking.
SWR Fittings (PVC-U)IS 14735 Dimensions &, sockets, Impact, VST, Heat reversion, Watertightness of joints, Visual/marking.

Polymer, Pipes & Fittings Testing FAQs

  • UPVC pipe — IS 4985
  • SWR pipe — IS 13592
  • Casing/Screen pipe — IS 12818
  • PVC Sewerage (non‑pressure) — IS 15328
  • HDPE (water supply) — IS 4984
  • HDPE Sewerage (up to 20–2500 mm) — IS 4984
  • HDPE Sewerage (> 2500 mm) — IS 14333
  • PPR — IS 15801
  • CPVC — IS 15778
  • CPVC fittings — IS 17546
  • PVC‑U fittings (water supply) — IS 7834
  • SWR fittings (PVC‑U) — IS 14735

Note: For gravity sewer applications, PVC‑U (IS 15328) and HDPE (IS 14333) are both used depending on client specifications and site conditions.

  • UPVC (IS 4985) — Dimensions; Hydrostatic (ambient/elevated); Opacity; Heat reversion; Impact (TIR); Flattening; VST.
  • SWR (IS 13592) — Dimensions; Impact; Heat reversion; VST; Joint water‑tightness; Visual.
  • Casing (IS 12818) — Dimensions; Hydrostatic; Collapse; Tensile of threaded joints; Impact; Thread gauging.
  • PVC Sewerage (IS 15328) — Dimensions; Ring stiffness/flexibility (as applicable); Impact; Heat reversion; VST; Joint water‑tightness.
  • HDPE (IS 4984) — Dimensions/SDR; Hydrostatic (20 °C and elevated); Density; MFR; Carbon black content/dispersion; OIT; ESCR; Tensile; Visual.
  • HDPE Sewerage (IS 14333) — Dimensions; Density; MFR; Carbon black; OIT; Leak‑tightness; ESCR; Visual.
  • PPR (IS 15801) — Dimensions; Hydrostatic at multiple temperatures (20–95 °C as grade/class); MFR; Thermal stability (e.g., OIT); Longitudinal reversion.
  • CPVC (IS 15778) — Dimensions; Hydrostatic (ambient/elevated); VST; Heat reversion; Impact (as applicable); Visual.
  • CPVC fittings (IS 17546) — Sustained and burst pressure; Thermal cycling/leak‑tightness; Dimensions/marking.
  • PVC‑U fittings (IS 7834) — Dimensions; Hydrostatic/leak tightness; VST; Heat reversion; Impact; Visual.
  • SWR fittings (IS 14735) — Dimensions; Impact; VST; Heat reversion; Water‑tightness; Visual.
  • Hydrostatic Pressure Test Apparatus (multi‑station) with temperature control
  • Falling Weight Impact Tester (TIR) for PVC/CPVC/HDPE
  • Ring Stiffness/Flexibility Test Rigs (non‑pressure sewer pipes)
  • Heat Reversion and Oven aging setup
  • Vicat Softening Temperature (VST) Tester
  • Melt Mass‑Flow Rate (MFR) Tester
  • Carbon Black Content Furnace and Dispersion kit (microscopy)
  • DSC for Oxidation Induction Time (OIT)
  • Universal Testing Machine (UTM) for tensile/ESCR fixtures
  • Leak‑tightness/Joint testing rigs (solvent weld, rubber ring, butt/electrofusion)

They assess long‑term performance: ESCR checks resistance to slow crack growth; OIT measures antioxidant stability; Carbon black content/dispersion ensures UV resistance and uniformity — all essential for durability in service.

IS 13592 covers PVC‑U SWR pipes for soil/waste/rainwater within building plumbing, emphasizing impact/VST/reversion and watertight joints. IS 15328 covers non‑pressure sewerage/drainage pipes, adding ring stiffness/flexibility for underground loads.

Manufacturing Excellence

15,000+

Machines Delivered

20+

Years Experience

10,000+

Sq. Ft Factory

100%

BIS Compliant